Hali ya upatikanaji: | |
---|---|
Wingi: | |
GD-R3035
GOLD
GD-R3035
GD-R3035 Automatic Cetane Number Tester for Biodiesel
Introduction:
The Automatic Cetane Number Tester can quickly and accurately determine the cetane number of biodiesel, with short detection time, accurate detection results, low noise, low operating and maintenance costs. A large number of test data show that the instrument fully meets the requirements of ASTM D613, ASTM D6890 and GB/T386 standards, and the cetane number tester has a wide detection range and accurate data. The entire inspection process of the instrument can be completed automatically within 20 minutes (including all preliminary preparation time). All test and statistical analysis results printed after each test are suitable for use by various research units, laboratories, refineries and other related departments.
vipengele:
1. The Automatic Cetane Number Tester is suitable for measuring the cetane number of diesel fuel for vehicles.
2. Set a variety of oil inspection modes. Diesel cetane number mode: standard diesel mode, improver diesel mode, biodiesel mode, catalytic diesel mode, and another six customer modes.
3. With calibration function, it can be carried out with standard oil, one point, two points and three points correction, which can automatically correct the system error.
4. With temperature adjustment function.
5. EL backlight display for easy use in dimly lit environments.
6. With automatic sleep, automatic shutdown and other power saving functions.
7. Can be connected to a micro printer (manufacturer specified model) to print measurement reports.
8. The measured values can be stored and managed.
9. Compact, portable and highly reliable, suitable for harsh operating environments, resistant to vibration, shock and electromagnetic interference.
10. The measurement time can be displayed.
Parameters:
Hapana. | Parameter Description | Numerical value |
1 | The measurement range of cetane number(CN), measured in CN (can be adjusted according to customer needs) | 20-100 |
2 | Allowable measurement error for cetane meter, CN unit (maximum) | ±1 |
3 | Floatable range of cetane meter measurement results, CN unit (maximum value) | ±0.5 |
4 | Measurement time (seconds) | <20 |
5 | Critical value of battery voltage too low V | 5.4 |
6 | Host, mm (length × width × height) | |
7 | Sensor, mm | 60х100 |
8 | Weight, Kg (maximum) | |
9 | Normal standby time (unit: hour) | 200 |
10 | Output method | LCD display, printout |
Real Picture of Automatic Cetane Number Tester for Biodiesel in our laboratory:
GD-R3035 Automatic Cetane Number Tester for Biodiesel
Introduction:
The Automatic Cetane Number Tester can quickly and accurately determine the cetane number of biodiesel, with short detection time, accurate detection results, low noise, low operating and maintenance costs. A large number of test data show that the instrument fully meets the requirements of ASTM D613, ASTM D6890 and GB/T386 standards, and the cetane number tester has a wide detection range and accurate data. The entire inspection process of the instrument can be completed automatically within 20 minutes (including all preliminary preparation time). All test and statistical analysis results printed after each test are suitable for use by various research units, laboratories, refineries and other related departments.
vipengele:
1. The Automatic Cetane Number Tester is suitable for measuring the cetane number of diesel fuel for vehicles.
2. Set a variety of oil inspection modes. Diesel cetane number mode: standard diesel mode, improver diesel mode, biodiesel mode, catalytic diesel mode, and another six customer modes.
3. With calibration function, it can be carried out with standard oil, one point, two points and three points correction, which can automatically correct the system error.
4. With temperature adjustment function.
5. EL backlight display for easy use in dimly lit environments.
6. With automatic sleep, automatic shutdown and other power saving functions.
7. Can be connected to a micro printer (manufacturer specified model) to print measurement reports.
8. The measured values can be stored and managed.
9. Compact, portable and highly reliable, suitable for harsh operating environments, resistant to vibration, shock and electromagnetic interference.
10. The measurement time can be displayed.
Parameters:
Hapana. | Parameter Description | Numerical value |
1 | The measurement range of cetane number(CN), measured in CN (can be adjusted according to customer needs) | 20-100 |
2 | Allowable measurement error for cetane meter, CN unit (maximum) | ±1 |
3 | Floatable range of cetane meter measurement results, CN unit (maximum value) | ±0.5 |
4 | Measurement time (seconds) | <20 |
5 | Critical value of battery voltage too low V | 5.4 |
6 | Host, mm (length × width × height) | |
7 | Sensor, mm | 60х100 |
8 | Weight, Kg (maximum) | |
9 | Normal standby time (unit: hour) | 200 |
10 | Output method | LCD display, printout |
Real Picture of Automatic Cetane Number Tester for Biodiesel in our laboratory: